COAXIAL CABLES AF - FLAME RETARDANT JACKETLegend


  Type CO 7 B90 AF CO 8 B 90
AF
CO 106 90
AF
CO 12 B90
AF
CO 165 N90
AF
Construction Properties  
inner conductor ø mm CU 0,70 CU O,80 CU 1,00 CU 1,13 CU 1,70
patented skin PECPECPECPECPEC
dielectric PEEPEEPEEPEEPEE
dielectric skin ø mmPEC 2,9PEC 3,5PEC 4,3PEC 4,9PEC 7,2
tape ALPALPALPALPALP
braid ø mmCU-Sn
3,4
CU-Sn
4,0
CU-Sn
4,9
CU-Sn
5,6
CU-Sn
7,9
braid coverage %9090909090
mayler PetPetPetPetPet
jacket ø mmPVC AF
4,3
PVC AF
5
PVC AF
6,0
PVC AF
6,7
PVC AF
10,0
minimum bending ratius ø mm20/5020/5020/5020/5075
total weight Kg/km28334654110
copper weight Kg/km1418232855
F screw connector code J 2943 J 2945 J 2946 J 2941 J 3026
F crimp connector codeJ 3053J 3055J 3056J 3057J 3065

Electric Properties

nominal impedance Ohm 75±3 75±3 75±3 75±3 75±2
capacitance pF/m52±252±252±252±252±2
velocity ratio %8585858585
structural return loss 20-860 MHz
dB>28>28>28>28>28
860-2500 MHz dB>22>22>24>24>23
screening attenuation dB>120>120>120>120>120
inner conductor resistance Ohm/Km453422177
outer conductor resistance Ohm/Km14131098
max voltage (spark test) kV2.52.5338
attenuation at 20° C at 50 MHz
dB/100 m6,25,24,53,62,7
at 200 MHz dB/100 m13,011,09,08,05,5
at 300 MHz dB/100 m16,014,010,89,56,8
at 470 MHz dB/100 m20,317,414,012,48,8
at 860 MHz dB/100 m28,023,419,316,812,2
at 1000 MHz dB/100 m30,025,520,818,013,0
at 1750 MHz dB/100 m40,034,028,024,918,0
a 2150 MHz dB/100 m44,538,031,527,520,2
at 2500 MHz dB/100 m48,540,033,529,522,0
at 3000 MHz dB/100 m53,045,037,433,024,7
conformity
EN 50117
RoHS
2-42-42-42-42-4
standard packing m200 B3200 B3100 B3100 B3100 B3
m-500 L0-250 B4250 L1
m-1000 L1-500 L1500 L2
Construction properties